Robust identification of multiple-input single-output system response for efficient pickup noise removal from tokamak diagnostics

Review of Scientific Instruments(2022)

Cited 1|Views27
No score
Abstract
Electromagnetic pickup noise in the tokamak environment imposes an imminent challenge for measuring weak diagnostic photocurrents in the nA range. The diagnostic signal can be contaminated by an unknown mixture of crosstalk signals from coils powered by currents in the kA range. To address this issue, an algorithm for robust identification of linear multi-input single-output (MISO) systems has been developed. The MISO model describes the dynamic relationship between measured signals from power sources and observed signals in the diagnostic and allows for a precise subtraction of the noise component. The proposed method was tested on experimental diagnostic data from the DIII-D tokamak, and it has reduced noise by up to 20 dB in the 1–20 kHz range.
More
Translated text
Key words
efficient pickup noise removal,tokamak diagnostics,robust identification,multiple-input,single-output
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined