Calculation of Parasitic Capacitance to Analyze Shaft Voltage of Electric Motor with Direct-Oil-Cooling System

Chan-Ho Kim, Sung-Bae Jun, Han-Joon Yoon, Nam-Ho Kim, Ho-Chang Jung, Rae-Eun Kim, Sang-Yong Jung

PROCESSES(2022)

引用 4|浏览2
暂无评分
摘要
In modern electric vehicles, electrical failure has become a critical problem that reduces the lifetime of traction motors. Moreover, traction motors with high-voltage and high-speed systems for a high power density have been aggravating the shaft voltage problems. This study identifies that direct-oil-cooling systems exacerbate this problem. To address this, an analytical method for calculating parasitic capacitance is proposed to determine the effects of cooling oil in a traction motor with a direct-oil-cooling system. Capacitance equivalent circuits are configured based on whether the slot is submerged in the cooling oil. In addition, an electric field decomposition method is applied to analyze the distortion of the electric field by the structure of the conduction parts in the motor. The results indicate that the parasitic capacitances of the traction motor are increased by the influence of the cooling oil resulting in an increase in the shaft voltage.
更多
查看译文
关键词
shaft voltage,parasitic capacitance,traction motor,direct-oil-cooling system,electric discharge machining,variable frequency drive,pulse width modulation,common-mode voltage