Weighty Matters: A Real-World Comparison of the Handtevy and Broselow Methods of Prehospital Weight Estimation

PREHOSPITAL AND DISASTER MEDICINE(2022)

引用 2|浏览2
暂无评分
摘要
Introduction: The majority of pediatric medications are dosed according to weight and therefore accurate weight assessment is essential. However, this can be difficult in the unpredictable and peripatetic prehospital care setting, and medication errors are common. The Handtevy method and the Broselow tape are two systems designed to guide Emergency Medical Services (EMS) providers in both pediatric patient weight estimation and medication dosing. The accuracy of the Handtevy method of weight estimation as practiced in the field by EMS has not been previously examined. Study Objective: The primary objective of this study was to examine the field performance of the Handtevy method and the Broselow tape with respect to prehospital patient weight estimation. Methods: This was a retrospective chart review of trauma and non-trauma patients transported by EMS to the emergency department (ED) of a quaternary care children's hospital from January 1, 2021 through June 30, 2021. Demographic data, ED visit information, prehospital weight estimation, and medication dosing were collected and analyzed. Scale-based weight from the ED was used as the standard for comparison. Results: A total of 509 patients <13 years of age were included in this study. The EMS providers using the Broselow method estimated patient weight to within +1-10% of ED scale weight in 51.3% of patients. When using the Handtevy method, the EMS providers estimated patient weight to within +1-10% of ED scale weight in 43.7% of patients. When comparing the Handtevy versus Broselow method of prehospital weight estimation, there was no significant association between method and categorized weight discrepancy (over, under, or accurate estimates - defined as within 10% of ED scale weight; P = .25) or percent weight discrepancy (P = .75). On average, prehospital weight estimation was 6.33% lower than ED weight with use of the Handtevy method and 6.94% lower with use of the Broselow method. Conclusion: This study demonstrated no statistically significant difference between the use of the Handtevy or Broselow methods with respect to prehospital weight estimation. While further research is necessary, these results suggest similar field performance of the Broselow and Handtevy methods.
更多
查看译文
关键词
body weights and measures, pediatric, prehospital emergency care
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要