Chrome Extension
WeChat Mini Program
Use on ChatGLM

The Effects of Lateral 45 degrees Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study

Journal of laparoendoscopic & advanced surgical techniques. Part A(2023)

Cited 0|Views10
No score
Abstract
Background: The aim of this study is to assess the extent of the increased intracranial pressure resulting from lateral decubitus and 45 degrees downward positioning using sonographic optic nerve sheath diameter (ONSD) in patients undergoing laparoscopic transperitoneal nephrectomy. In addition, we evaluated the effect of the carbon dioxide pneumoperitoneum (CO2PP) on ONSD. Materials and Methods: Twenty-four adults were enrolled in this prospective observational study. Longitudinal and transverse ONSDs were measured for each eye by ocular ultrasonography. The values were noted in supine position (T0), 20 minutes after induction of anesthesia (T1), after insufflation of the abdomen in lateral 45 degrees head-down position (T2), at 30-minute intervals during surgery (T3-T4-T5), during lateral 45 degrees head-down position after CO2 exsufflation (T6), before awakening while supine (T7), and at postoperative 24th hour (T8). Hemodynamic and respiratory parameters were investigated at the measurement time points. Results: Average ONSD values for the lower eye was T0 = 4.27 +/- 0.4 mm, T1 = 4.56 +/- 0.6 mm, T2 = 4.84 +/- 0.6 mm, T3 = 4.91 +/- 0.4 mm, T4 = 4.99 +/- 0.5 mm, T5 = 4.97 +/- 0.5 mm T6 = 4.96 +/- 0.5 mm, T7 = 4.76 +/- 0.4 mm, T8 = 4.36 +/- 0.5 mm and for the upper eye was T0 = 4.24 +/- 0.4 mm, T1 = 4.39 +/- 0.5 mm, T2 = 4.54 +/- 0.5 mm, T3 = 4.60 +/- 0.4 mm, T4 = 4.66 +/- 0.4 mm, T5 = 4.72 +/- 0.7 mm, T6 = 4.68 +/- 0.4 mm, T7 = 4.52 +/- 0.4 mm, T8 = 4.30 +/- 0.4 mm (P < .001). Conclusion: In our study, we observed a significant increase in ONSD within minutes after the patient was placed in a head-down position. We also observed that the difference increased more with CO2PP and was proportional to the length of the surgery. We found that it regressed to initial levels at the postoperative 24th hour.
More
Translated text
Key words
optic nerve sheath diameter, laparoscopic transperitoneal nephrectomy, lateral 45 degrees head-down position, carbon dioxide pneumoperitoneum, ocular sonography
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined