Efficacy and Safety of an Extravascular Implantable Cardioverter-Defibrillator.

The New England journal of medicine(2022)

引用 23|浏览6
暂无评分
摘要
BACKGROUND:The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS:We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS:A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS:In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要