谷歌Chrome浏览器插件
订阅小程序
在清言上使用

Determination of polycyclic aromatic hydrocarbons in surface waters by high performance liquid chromatography previous to preconcentration through solid-phase extraction by using polymeric monoliths

Emilia Frickel Critto, Giselle Medina,Mario Reta,Agustin Acquaviva

Journal of Chromatography A(2022)

引用 4|浏览5
暂无评分
摘要
A simple, sensitive and reproducible solid-phase extraction method using plastic cartridges containing a monolithic sorbent (m-SPE), coupled to reverse phase liquid chromatography analysis, aiming to deter-mine fifteen polycyclic aromatic hydrocarbons in surface water samples, was developed. The sorbent was easily prepared through a thermal polymerization reaction by using a mixture of n-butyl methacrylate as non-polar monomer and ethylene glycol dimethacrylate as crosslinker contained in a typical Polypropy-lene syringe cartridge. The effect of different parameters (type of hydrophobic monomer, elution solvent, sample volume, sorbent amount and sorbent load capacity) on the extraction efficiency was optimized. The optimal conditions were achieved by using n-butyl methacrylate as monomer, tetrahydrofurane (THF) as solvent for sorbent cleaning, THF:acetone (1:1) as elution solvent, 25.00 mL of sample volume, 600 mu L of the polymerization mixture and 60 mu g L -1 as sample loading capacity. Finally, the sorbent charge ca-pacity, the reusability of the cartridges and the extraction efficiency of the m-SPE monolith, as com-pared with a typical C8 cartridge, were evaluated. Under the optimized experimental conditions, enrich-ment factors were between 76 and 103, relative recovery factors from 78 to 103%, accuracy values in the range of 58 to 98%, and inter-batch reproducibility values from between 2 and 10%, were obtained. The limits of detection and quantification were obtained by two different procedures: the signal to noise (S/N) ratios (3 and 10, respectively) and the IUPAC convention. The lowest LOD and LOQ values, obtained with the S/N ratios, were between 0.02 and 1.00 mu g L -1, respectively whereas with the IUPAC conven-tion the values were between 0.07 and 5 mu g L -1. Using this procedure, several PAHs could be detected in the surface water sample taken from a river stream located in La Plata city (Buenos Aires Province, Argentina).(c) 2022 Elsevier B.V. All rights reserved.
更多
查看译文
关键词
Polycyclic aromatic hydrocarbons,High performance liquid,chromatography-fluorescence detection,Organic polymer monoliths,m-SPE,Surface water samples
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要