谷歌浏览器插件
订阅小程序
在清言上使用

The sonographic quantitative assessment of the deltoid muscle to detect type 2 diabetes mellitus: a potential noninvasive and sensitive screening method?

BMC Endocrine Disorders(2022)

引用 1|浏览2
暂无评分
摘要
Background In our previous published study, we demonstrated that a qualitatively assessed elevation in deltoid muscle echogenicity on ultrasound was both sensitive for and a strong predictor of a type 2 diabetes (T2DM) diagnosis. This study aims to evaluate if a sonographic quantitative assessment of the deltoid muscle can be used to detect T2DM. Methods Deltoid muscle ultrasound images from 124 patients were stored: 31 obese T2DM, 31 non-obese T2DM, 31 obese non-T2DM and 31 non-obese non-T2DM. Images were independently reviewed by 3 musculoskeletal radiologists, blinded to the patient’s category. Each measured the grayscale pixel intensity of the deltoid muscle and humeral cortex to calculate a muscle/bone ratio for each patient. Following a 3-week delay, the 3 radiologists independently repeated measurements on a randomly selected 40 subjects. Ratios, age, gender, race, body mass index, insulin usage and hemoglobin A 1c were analyzed. The difference among the 4 groups was compared using analysis of variance or chi-square tests. Both univariate and multivariate linear mixed models were performed. Multivariate mixed-effects regression models were used, adjusting for demographic and clinical variables. Post hoc comparisons were done with Bonferroni adjustments to identify any differences between groups. The sample size achieved 90% power. Sensitivity and specificity were calculated based on set threshold ratios. Both intra- and inter-radiologist variability or agreement were assessed. Results A statistically significant difference in muscle/bone ratios between the groups was identified with the average ratios as follows: obese T2DM, 0.54 ( P < 0.001); non-obese T2DM, 0.48 ( P < 0.001); obese non-T2DM, 0.42 ( P = 0.03); and non-obese non-T2DM, 0.35. There was excellent inter-observer agreement (intraclass correlation coefficient 0.87) and excellent intra-observer agreements (intraclass correlation coefficient 0.92, 0.95 and 0.94). Using threshold ratios, the sensitivity for detecting T2DM was 80% (95% CI 67% to 88%) with a specificity of 63% (95% CI 50% to 75%). Conclusions The sonographic quantitative assessment of the deltoid muscle by ultrasound is sensitive and accurate for the detection of T2DM. Following further studies, this process could translate into a dedicated, simple and noninvasive screening method to detect T2DM with the prospects of identifying even a fraction of the undiagnosed persons worldwide. This could prove especially beneficial in screening of underserved and underrepresented communities.
更多
查看译文
关键词
Type 2 diabetes mellitus, Diabetes screening, Musculoskeletal ultrasound, Deltoid muscle, Shoulder, Muscle echogenicity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要