Safety profile of repeated infusion of platelet-like nanoparticles in healthy dogs

AMERICAN JOURNAL OF VETERINARY RESEARCH(2022)

引用 1|浏览9
暂无评分
摘要
OBJECTIVE To assess the safety and efficacy of the platelet-like nanoparticle (PLN), and to assess its safety in repeated administration. ANIMALS 6 purpose-bred dogs. PROCEDURES The PLN was administered IV at 3 different doses using a randomized crossover design. Each dog received a full dose of 8 X 1010 particles/10 kg, half dose, and 10 times the dose, with a 14-day washout period between doses. Biochemical, prothrombin time, partial thromboplastin time, and fibrinogen analyses were performed at baseline and 96 hours postinfusion. A CBC, kaolin-activated thromboelastography, platelet function assay closure time, and buccal mucosal bleeding time were performed at baseline and 1, 6, 24, 48, 72, and 96 hours postinfusion. RESULTS No significant changes were observed over time in the thromboelastography parameters, closure time, and buccal mucosal bleeding time. After the administration of the half dose, hematocrit levels decreased significantly at 1, 6, 24, 48, and 96 hours, with all values within the reference range. The platelet count was decreased significantly at hours 1, 6, 24, 48, and 72 after administration of the half dose, with values less than the reference range at all hours but hour 72. No significant changes in serum biochemistry, coagulation panel, and fibrinogen were observed for all doses. No adverse events were noted during the first infusion. Three dogs experienced transient sedation and nausea after repeat infusion.