Recurrent environmental contamination in a centralized radiopharmacy unit by Achromobacter spp: Results of a large microbiological investigation.

American journal of infection control(2022)

引用 0|浏览6
暂无评分
摘要
BACKGROUND:Radiopharmaceuticals preparation unit, such as every aseptic preparation units, are strictly monitored in terms of microbiological contamination. Despite all biocontamination control procedures, our radiopharmacy unit faced repeated environmental contamination by Achromobacter spp which necessitated a large environmental investigation. METHODS:Microbiological controls were carried out using Count Tact agars (Biomérieux) for flat surfaces, dry swabbing for hard to reach areas and containers were filled with a sterile water solution (then filtrated on 0.45 µm membrane and seeded). Microbiological identification was performed by mass spectrometry (MALDI-TOF-MS, Brucker) on each positive sample. RESULTS:Achromobacter spp was found in 10% of the 413 samples during the 8 months investigation period. The proportion of positive samples was stable among time but their location was unpredictable. The highest inoculum was finally found in the buckets used for biocleaning. DISCUSSION:Samples from cleaning buckets taken by dry swabbing were at first negative, but the use of a non-routinely used sampling method allowed to discover the reservoir of this persistent contamination. CONCLUSION:This investigation alerted us on the high microbiological risk associated with reusable plastic containers and the importance of a sampling method adapted to critical locations.