Optimising MWA EoR data processing for improved 21-cm power spectrum measurements-fine-tuning ionospheric corrections

PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF AUSTRALIA(2022)

Cited 0|Views15
No score
Abstract
The redshifted cosmological 21-cm signal emitted by neutral hydrogen during the first billion years of the universe is much fainter relative to other galactic and extragalactic radio emissions, posing a great challenge towards detection of the signal. Therefore, precise instrumental calibration is a vital prerequisite for the success of radio interferometers such as the Murchison Widefield Array (MWA), which aim for a 21-cm detection. Over the previous years, novel calibration techniques targeting the power spectrum paradigm of EoR science have been actively researched and where possible implemented. Some of these improvements, for the MWA, include the accuracy of sky models used in calibration and the treatment of ionospheric effects, both of which introduce unwanted contamination to the EoR window. Despite sophisticated non-traditional calibration algorithms being continuously developed over the years to incorporate these methods, the large datasets needed for EoR measurements require high computational costs, leading to trade-offs that impede making use of these new tools to maximum benefit. Using recently acquired computation resources for the MWA, we test the full capabilities of the state-of-the-art calibration techniques available for the MWA EoR project, with a focus on both direction-dependent and direction-independent calibration. Specifically, we investigate improvements that can be made in the vital calibration stages of sky modelling, ionospheric correction, and compact source foreground subtraction as applied in the hybrid foreground mitigation approach (one that combines both foreground subtraction and avoidance). Additionally, we investigate a method of ionospheric correction using interpolated ionospheric phase screens and assess its performance in the power spectrum space. Overall, we identify a refined RTS calibration configuration that leads to an at least 2 factor reduction of the EoR window power contamination at the 0.1 hMpc(-1) scale. The improvement marks a step further towards detecting the 21-cm signal using the MWA and the forthcoming SKA low telescope.
More
Translated text
Key words
interferometric,radio telescopes,reionization,techniques: statistical
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined