Chrome Extension
WeChat Mini Program
Use on ChatGLM

Infusion-assisted evacuation of submacular hemorrhage.

Retinal cases & brief reports(2023)

Cited 0|Views5
No score
Abstract
PURPOSE:To report a novel surgical technique for evacuating submacular hemorrhage using the infusion stream of a 25-gauge vitrectomy system. METHODS:Surgical case and video. RESULTS:A 54-year-old man was taken to the operating room for a total hyphema, nonclearing vitreous hemorrhage, and elevated intraocular pressure after multiple tractional retinal detachment repairs by an outside surgeon. Intraoperatively, the hyphema and vitreous hemorrhage were cleared, and the source of bleeding was discovered to be an avulsed vessel through a pre-existing retinal break just superior to the optic nerve. A large submacular hemorrhage was also present that was unable to be drained through the break by aspiration alone. With the vitreous cavity under fluid, the infusion cannula was manipulated to guide the infusion stream onto the macula. The stream was directed in a distal to proximal manner toward the retinal break, and the submacular blood was successfully expressed out through the break. Postoperatively, the retina remained attached with almost complete resolution of the submacular hemorrhage. CONCLUSION:Using the mechanical pressure of the infusion stream can be an effective method for evacuating large subretinal hemorrhages.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined