Trade-off study between risk and benefit in safety devices for hydrogen refueling stations using a dynamic physical model

International Journal of Hydrogen Energy(2022)

Cited 5|Views8
No score
Abstract
As hydrogen refueling stations become increasingly common, it is clear that a high level of economic efficiency and safety is crucial to promoting their use. One way to reduce costs is to use a simple orifice instead of an excess flow valve, which Japanese safety regulations have identified as a safety device. However, there is concern about its effect on refueling time and on risk due to hydrogen leakage. To clarify the effect, we did a study of model-based refueling time evaluation and quantitative risk assessment for a typical refueling station. This study showed that an orifice is an effective alternative safety device. The increase in refueling time was less than 10%, based on simulations using a dynamic physical model of the station. Neither was there a significant difference in the risk between a configuration with excess flow valves and one with an orifice.
More
Translated text
Key words
Hydrogen refueling station,Safety device,Dynamic physical model,Quantitative risk assessment