Plasmonic Gold Chip for Multiplexed Detection of Ovarian Cancer Biomarker in Urine

Minwen Chen,Tao Liao, Linsheng Zeng, Zhongyi Zeng,Qinglai Yang,Guoxin Wang

Chemical Research in Chinese Universities(2022)

引用 1|浏览3
暂无评分
摘要
Human epididymal protein 4(HE4), carbohydrate antigen 125 (CA125) and osteopontin(OPN) are three key biomarkers in detecting ovarian cancer. To explore the diagnosis value of combined detection of these three biomarkers for ovarian cancer, we developed a multiplexed assay on a plasmonic gold(pGOLD) platform for measuring HE4, CA125 and OPN in urine. The receiver operator characteristic(ROC) curve was drawn, and the diagnosis values of each biomarker alone or in combination for ovarian cancer were evaluated. In the analysis to distinguish ovarian cancer from other gynecological cancers, ovarian cysts and healthy people, the sensitivities of HE4, CA125 and OPN were 72.55%, 52.82% and 68.63%, the specificity values were 95.06%, 87.65% and 90.12%, while the areas under the curve(AUC) were 0.85, 0.75 and 0.77, respectively. The sensitivity and specificity for combination detection of the three markers were 90.20% and 80.25%. The detection methods of HE4, CA125 and OPN based on plasma fluorescence enhanced chip showed good analytic and diagnostic performance, and provided a non-invasive method for the diagnosis of ovarian cancer.
更多
查看译文
关键词
Plasmonic gold chip,Urine,Ovarian cancer,Multiplexed detection