Relationship between tissue characteristics and mechanical properties of coronary plaques: a comparison between integrated backscatter intravascular ultrasound (IVUS) and speckle-tracking IVUS

Heart and vessels(2022)

引用 0|浏览5
暂无评分
摘要
High-risk coronary plaques have certain morphological characteristics. Thus, comprehensive assessment is needed for the risk stratification of plaques in patients with coronary artery disease. Integrated backscatter intravascular ultrasound (IB-IVUS) has been used successfully used to evaluate the tissue characteristics of coronary plaques; however, the mechanical properties of plaques have been rarely assessed. Therefore, we developed Speckle-tracking IVUS (ST-IVUS) to evaluate the mechanical properties of coronary plaque. This study aimed to evaluate the relation between the tissue characteristics of coronary plaques using IB-IVUS and their mechanical properties using ST-IVUS. We evaluated 95 non-targeted plaques in 95 patients undergoing elective percutaneous coronary intervention to the left anterior descending artery. We set regions of interest (ROIs) in the cross-sectional images of coronary plaques where we divided 120 degree plaques into four quadrants (every 30 degrees), with the center at the area of maximum atheroma thickness. We measured relative calcification area (%CA, relative fibrous area (%FI) and relative lipid pool area (%LP) in a total of 380 ROIs. In ST-IVUS analysis, we measured strain in the circumferential direction of the lumen area (LA strain: %), the external elastic membrane area strain (EEM strain: %), and strain in the radial direction (radial strain: %). On global cross-sectional area IB-IVUS analysis, the %CA was 1.2 ± 1.2%; the %FI was 49.0 ± 15.9%, and the %LP was 49.7 ± 16.5%. In ST-IVUS analysis, the LA strain was 0.67 ± 0.43%; the EEM strain was 0.49 ± 0.33%, and the radial strain was 2.02 ± 1.66%. On regional analysis, the %LP was not associated with the LA strain ( r = − 0.002 p = 0.97), the EEM strain ( r = − 0.05 p = 0.35), or with the radial strain ( r = − 0.04 p = 0.45). These trends were seen between the %FI and the LA strain ( r = 0.02 p = 0.74), the %FI and the EEM strain ( r = 0.05 p = 0.35), and the %FI and the radial strain ( r = 0.04 p = 0.50). A significant correlation was only observed between the %CA and the LA strain ( r = − 0.15 p = 0.0038). Our findings indicate that the associations between mechanical properties and tissue characteristics lacked statistical significance, more often than not, and that it is necessary to evaluate the mechanical properties as well as plaque characteristics for risk stratification of coronary plaques.
更多
查看译文
关键词
Coronary artery disease,Integrated backscatter IVUS,Mechanical properties,Speckle-tracking IVUS,Tissue characteristics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要