Abstract
•A DTS system is utilized for monitoring concrete temperature at different depths.•The effect of the insulation layer is within 40 cm from the surface of pouring block.•Insulation effect is affected by materials, thickness, time, and space position.
More
Translated text
Key words
Surface thermal insulation,Arch dam,Concrete pouring block,Optical fibre temperature measurement,Equivalent heat transfer method,Numerical simulation