ObjectiveCoronavirus disease 2019 has highlighted the lack of knowledge on aerosol exposure during respiratory activity and aerosol-generating procedures. This study sought to determine the aerosol concentrations generated by coughing to better understand, and to set a standard for studying, aerosols generated in medical procedures. MethodsAerosol exposure during coughing was measured in 37 healthy volunteers in the operating theatre with an optical particle sizer, from 40 cm, 70 cm and 100 cm distances. ResultsAltogether, 306 volitional and 15 involuntary coughs were measured. No differences between groups were observed. ConclusionMany medical procedures are expected to generate aerosols; it is unclear whether they are higher risk than normal respiratory activity. The measured aerosol exposure can be used to determine the risk for significant aerosol generation during medical procedures. Considerable variation of aerosol generation during cough was observed between individuals, but whether cough was volitional or involuntary made no difference to aerosol production.