Neonatal Cord Tox Panel and Maternal Perinatal Fentanyl Exposure: A Retrospective Chart Review

American Journal of Analytical Chemistry(2021)

引用 2|浏览0
暂无评分
摘要
Objective: The specific aim of this study was to determine if the currently available cutoff for fentanyl in umbilical cord (UC) was appropriate to distinguish illicit fentanyl exposure from therapeutic in-hospital administration of fentanyl.Study Design: Medical record review was conducted for perinatal administration of fentanyl and the detection of fentanyl in the corresponding routine UC toxicology.Specimens were initially tested with immunoassay followed by mass spectrometry (n = 62).Result: Excluding a single specimen that was confirmed positive, specimens were below the assays' limit of quantification.The immunoassay's mean b/b 0 for the cases that received and did not receive fentanyl prior to delivery was 91.3% ± 10.6% and 98.2% ± 6.5%, respectively (p = 0.003).Conclusion: We demonstrated that UC is a suitable specimen type for the detection of fentanyl and that the cutoff selected adequately identifies illicit fentanyl use while not flagging cases where fentanyl was administered by the hospital prior to birth.