652. Comparison of QuantiFERON-TB Gold Plus and T-SPOT.TB in the Diagnosis of Active Tuberculosis

Open Forum Infectious Diseases(2021)

引用 0|浏览10
暂无评分
摘要
Abstract Background Objective: To compare the accuracy of Quantiferon ®- TB Gold Plus (QFT-Plus) and T-SPOT.TB in the diagnosis of active tuberculosis (ATB). Methods From April 2020 to May 2021, patients with pathologically confirmed or clinically diagnosed ATB in Peking Union Medical College Hospital and Beijing Chest Hospital were enrolled as case group, while patients excluded from ATB in the same period were enrolled as control group, The clinical and laboratory information were collected. QFT-Plus and T-SPOT. TB were tested simultaneously to evaluate the consistency of the results and compare the sensitivity, specificity, predictive values and likelihood ratios for diagnosing ATB. Results Fifty-seven ATB patients and 159 non-ATB patients were included. 33 (57.9%) ATB patients were pathologically confirmed. The proportions of indeterminate results in QFT-Plus and T-SPOT.TB were 3.7% vs 0%, respectively. The agreement between the results of the QFT-Plus and T-SPOT.TB was substantial (kappa=0.644, p<0.001). The area under the ROC curve of the QFT-Plus and T-SPOT.TB for diagnosing ATB was 0.759 (95%CI 0.689-0.829) vs 0.810 (95%CI 0.742-0.877), respectively, and there was no significant difference (p=0.303). the sensitivity of the QFT-Plus and T-SPOT.TB was 85.2% vs 89.5%, while the specificity was 61.7% vs 52.2%, respectively. In 33 Patients with pathologically confirmed ATB, the sensitivity of QFT-Plus and T-SPOT.TB was 87.9% vs 93.9% (p=0.669), respectively. In 78 patients (36.1%) who received glucocorticoid / immunosuppressive / biological agents, the positive rate of QFT-Plus was 35.9% (28/78), which was significantly lower than that of those who did not receive these agents (77 / 138pm,55.8%) (p=0.005), but there was no significant difference in the positive rate of T-SPOT.TB between the two groups (52.6% vs. 62.3%, p=0.162). The positive rate for both tests was independent of the peripheral blood lymphocyte count (p=0.675 for QFT-Plus vs. P=0.138 for T-SPOT.TB). Conclusion There was no significant difference between the QFT-Plus and T-SPOT.TB in the diagnosis of ATB. QFT-plus might be prone to indeterminate results and influenced by the immunosuppressive status. The results need to be verified by a prospective cohort study with large sample. Disclosures All Authors: No reported disclosures
更多
查看译文
关键词
Diagnosis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要