[Exploratory study on detection of drug resistance of Mycobacterium tuberculosis in sputum specimens by next-generation sequencing].

Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases(2022)

引用 0|浏览24
暂无评分
摘要
To compare the diagnostic performance of next-generation sequencing (NGS) detection methods in sputum samples and strains, in order to explore the feasibility of the NGS method to detect drug resistance in sputum specimens. In this retrospective study, the sputum specimens and corresponding clinical isolates of 50 pulmonary tuberculosis patients admitted to Beijing Chest Hospital from January 2017 to December 2017 were collected. The gene mutations of , , , , , , , , and in sputum specimens and corresponding clinical isolates were detected by NGS method. The phenotypic drug susceptibility test (DST) of the strains was carried out by the proportion method. Using DST results as a reference, the sensitivity, specificity, positive predictive value and negative predictive value of the NGS method for clinical strains and sputum specimens, as well as the consistency statistic () with phenotype DST were calculated respectively. The Chi-square test was used to compare the accuracy of the NGS testing in sputum samples and strain samples. The results showed that (63.83%, 30/47) and (57.45%, 27/47) were the most common mutated genes, followed by (46.81%, 22/47)(29.79%, 14/47), (27.66%, 13/47), (21.28%, 10/47), (12.77%, 6/47), (8.51%, 4/47), and promoter(19.15%, 9/47), promoter region (12.77%, 6/47) mutation. when the NGS method was compared with the resistance phenotype of isoniazid, rifampicin, ethambutol, second-line injectable drugs (streptomycin, capreomycin, kanamycin, amikacin), levofloxacin, the sensitivity were 85.71%, 91.67%, 77.78%, 81.82%, 100.00%, 87.50%, 100.00%, 69.23%, and the specificity were 100.00%, 94.12, 87.50%, 89.47%, 97.06%, 96.97%, 94.29%, 89.29% in sputum samples, while in strain samples, the sensitivity were 92.86%, 100.00%, 81.82%, 86.96%, 88.89%, 80.00%, 100.00%, 85.71%. The specificity were 100.00%, 92.86%, 87.10%, 94.74%, 100.00%, 100.00%, 97.14%, 92.86%. Compared with the phenotypic drug susceptibility results, the NGS method has better detection performance for isoniazid, rifampicin, capreomycin, kanamycin, and amikacin in sputum specimens (≥0.75); while among the strains, the NGS method had a good detection performance for isoniazid, rifampicin, streptomycin, capreomycin, kanamycin, amikacin and levofloxacin (≥0.75). With the accuracy of the NGS method for detecting strains as a reference, there was no statistically significant difference in the accuracy of all drug resistance detected between strains and sputum specimens. This study showed that the NGS technology was effective in predicting the resistance of isoniazid, rifampicin, and second-line injectable drugs (capreomycin, kanamycin and amikacin) by detecting sputum samples and strain genotypes, suggesting the feasibility and potential of direct detection of sputum samples by the NGS method as an early detection method for drug resistance.
更多
查看译文
关键词
Mycobacterium tuberculosis,Drug resistance,Next-generation sequencing,Sputum specimen
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要