Multifrequency AC Magnetic Flux Leakage Testing for the Detection of Surface and Backside Defects in Thick Steel Plates

IEEE Magnetics Letters(2022)

引用 9|浏览4
暂无评分
摘要
The detection of surface and backside defects in steel plates is essential for safety maintenance. Current ac magnetic flux leakage (ACMFL) testing systems generally operate at a high frequency but cannot detect backside defects owing to the skin effect. Low-frequency ACMFL is limited by low sensitivity and low efficiency in detecting deep defects. This letter presents a multifrequency ACMFL testing method combined with the merits of low- and high-frequency excitation to detect surface and backside defects. In early work, the optimal frequency for detecting the surface defect with a depth of 4 mm or less was 400 Hz. Through simulation analysis, the optimal low frequency for detecting backside defects is determined. Additionally, the influence of the excitation intensity on the response signal is investigated. Relatively small excitation power should be used to obtain a reliable detection waveform. Finally, the experimental results of surface and backside defects detection validated the practicality of the method.
更多
查看译文
关键词
Magnetic instruments,magnetic flux leakage,surface and backside defects detection,multifrequency,steel plate