Comparison Between 1.5-T and 3.0-T MRI for the Diagnosis of Placenta Accreta Spectrum Disorders

Diagnostic and interventional imaging(2022)

Cited 2|Views20
No score
Abstract
Purpose: Accurate antenatal diagnosis of placenta accreta spectrum (PAS) is important for optimal management. The purpose of this study was to compare the respective capabilities of 1.5-T and 3.0-T MRI in the diagnosis of PAS. Materials and methods: Between March 2016-March 2021, 190 pregnant women at high risk for PAS underwent dedicated prenatal MRI with either 1.5-T or 3.0-T units at a tertiary imaging center. Cesarian section and MRI were performed less than 6 weeks from each other. Prospectively collected data were evaluated by two experienced genitourinary radiologists for presence and extent of PAS. A comparative study was designed to investigate differences in predictive ability between 1.5-T and 3.0-T MRI groups. Sensitivity, specificity, accuracy, negative and positive prognostic values relative to intraoperative/histological findings, were computed for both groups and were compared with chi-square (chi 2) test. Interobserver agreement was estimated using Kappa test. Results: One hundred-eighty-two gravid women were included in the study; of these, 91/182 (50%) women were evaluated with 1.5-T (mean age, 35 +/- 5.1 [SD] years; mean gestational age: 32.5 weeks) and 91/182 (50%) with 3.0-T MRI (mean age, 34.9 +/- 4.9 [SD] years; mean gestational age, 32.1 weeks). 1.5-T MRI yielded 95.7% sensitivity (95% CI: 87.8-99.1) and 81.8% specificity (95% CI: 59.8) and 3.0-T MRI 93.8% sensitivity (95% CI: 86.0-97.9) and 83.3% specificity (95% CI: 48.2-97.7) for PAS identification, with no differences between the two groups (P = 0.725 and P > 0.999, respectively). MRI showed excellent predictive ability for detecting extrauterine placental spread with 100% sensitivity (95% CI: 89.4-100.0), 96.7% specificity (95% CI: 88.1-99.6) for 1.5-T and 97% sensitivity (95% CI: 84.2-99.9), 96.7% specificity (95% CI: 88.1-99.6) for 3.0-T without differences between the two groups (P > 0.999). Interobserver agreement was excellent for both groups. The most frequently detected MRI signs of PAS for both 1.5-T and 3.0-T groups were placental heterogeneity (n = 85, 93.5% vs. n = 90, 98.9%; P = 0.413), and intraplacental fetal vessels (n = 64, 70.3% vs. n = 65, 71.4%; P = 0.870). Conclusion: This study suggests that 3.0-T MRI and 1.5-T MRI are equivalent for the diagnosis of PAS. (C) 2022 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
More
Translated text
Key words
Placenta accreta spectrum,Invasive placenta,Placenta accreta,Pregnancy,Magnetic resonance imaging
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined