The effect of amplitude modulation index on harmonic distortion in unipolar SHEPWM inverter

Journal of Physics: Conference Series(2021)

Cited 0|Views2
No score
Abstract
The appearance of low order odd harmonic in the AC power line can be mitigated by projecting a proper switching angle during the conversion of the inverter. The switching angles can be obtained by solving the numerical nonlinear equation using numerous solving techniques and algorithms. Several studies shows the value of harmonic significantly increase whenever the amplitude modulation decrease for the SPWM switching scheme of the inverter. However, this topic has not yet covered in the single-phase SHEPWM inverter. This paper is to study the effect of the amplitude modulation index towards the harmonic distortion in the SHEPWM switching technique. To solve the numerical equations, MATLAB code is used to produce the specific switching angles to drive the inverter by solving the numerical equations. The validation of results thru hardware implementation using EZDSPTMS320F28335 to produce the digital signal for controlling the inverter. The targeted low order harmonic to be eliminated are the 3rd, 5th and 7th and three four amplitude modulation indices will be compared and observed in term of total harmonic distortion. The THD results for amplitude modulations 0.6, 0.7, 0.8 and 0.9 are 17.50%, 15.10%, 13.30% and 10.63%.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined