Influence of a remelt scan strategy on the microstructure and fatigue behaviour of additively manufactured biomedical Ti65Ta efficiently assessed using small scale specimens

INTERNATIONAL JOURNAL OF FATIGUE(2022)

引用 4|浏览5
暂无评分
摘要
Due to its high cost and demanding characteristics, Tantalum requires unique processing techniques and is restricted to small parts. In the present work, Ti65Ta was additively manufactured as a new potential material for small biomedical implants. Assessment of the effects of a remelt scanning strategy was solely accomplished by testing of small mechanical specimens. Yield strength was achieved superior to either L-PBF pure Ti or Ta and low-cycle fatigue behaviour was similar to that of L-PBF Ti-6Al-4 V. The Ti65Ta alloy is a good candidate for a new gold standard alloy for small bone interfacing implants.
更多
查看译文
关键词
Tantalum,Titanium,Laser powder bed fusion,Fatigue,Biomedical