Harmonization of technical image quality in computed tomography: comparison between different reconstruction algorithms and kernels from six scanners

BIOMEDICAL PHYSICS & ENGINEERING EXPRESS(2022)

Cited 3|Views1
No score
Abstract
Purpose. The radiology department faces a large number of reconstruction algorithms and kernels during their computed tomography (CT) optimization process. These reconstruction methods are proprietary and ensuring consistent image quality between scanners is becoming increasingly difficult. This study contributes to solving this challenge in CT image quality harmonization by modifying and evaluating a reconstruction algorithm and kernel matching scheme. Methods. The Catphan 600 phantom was scanned with six different CT scanners from four vendors. The phantom was scanned with volumetric CT dose indices (CTDIvols) of 10 mGy and 40 mGy, and the data were reconstructed using 1 mm and 5 mm slices with each combination of reconstruction algorithm, body region kernel, and iterative and deep learning reconstruction strength. A matching scheme developed in previous research, which utilizes the noise power spectrum (NPS) and modulation transfer function (MTF), was modified based on our organization's needs and used to identify the matching reconstruction algorithms and kernels between different scanners. Results. The matching paradigm produced good matching results, and the mean +/- standard deviation (median) matching function values for the different acquisition settings were (a value of 1 indicates a perfect match): CTDIvol 10 mGy, 1 mm slice: 0.78 +/- 0.31(0.94); CTDIvol 10 mGy, 5 mm slice: 0.75 +/- 0.33 (0.93); CTDIvol 40 mGy, 1 mm slice: 0.81 +/- 0.28 (0.95); CTDIvol 40 mGy, 5 mm slice: 0.75 +/- 0.33 (0.93). In general, soft reconstruction kernels, i.e., noise-reducing kernels that reduce sharpness, of one vendor were matched with the soft kernels of another vendor, and vice versa for sharper kernels. Conclusions. Combined quantitative assessment of NPS and MTF allows effective strategy for harmonization of technical image quality between different CT scanners. A software was also shared to support CT image quality harmonization in other institutions.
More
Translated text
Key words
computed tomography, image quality, modulation transfer function, noise power spectrum, reconstruction
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined