Coronary Computed Tomography Angiography-Based Calcium Scoring In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System

INVESTIGATIVE RADIOLOGY(2022)

引用 36|浏览20
暂无评分
摘要
Purpose The aim of this study was to evaluate coronary computed tomography angiography (CCTA)-based in vitro and in vivo coronary artery calcium scoring (CACS) using a novel virtual noniodine reconstruction (PureCalcium) on a clinical first-generation photon-counting detector-computed tomography system compared with virtual noncontrast (VNC) reconstructions and true noncontrast (TNC) acquisitions. Materials and Methods Although CACS and CCTA are well-established techniques for the assessment of coronary artery disease, they are complementary acquisitions, translating into increased scan time and patient radiation dose. Hence, accurate CACS derived from a single CCTA acquisition would be highly desirable. In this study, CACS based on PureCalcium, VNC, and TNC, reconstructions was evaluated in a CACS phantom and in 67 patients (70 [59/80] years, 58.2% male) undergoing CCTA on a first-generation photon counting detector-computed tomography system. Coronary artery calcium scores were quantified for the 3 reconstructions and compared using Wilcoxon test. Agreement was evaluated by Pearson and Spearman correlation and Bland-Altman analysis. Classification of coronary artery calcium score categories (0, 1-10, 11-100, 101-400, and >400) was compared using Cohen kappa. Results Phantom studies demonstrated strong agreement between CACS(PureCalcium) and CACS(TNC) (60.7 +/- 90.6 vs 67.3 +/- 88.3, P = 0.01, r = 0.98, intraclass correlation [ICC] = 0.98; mean bias, 6.6; limits of agreement [LoA], -39.8/26.6), whereas CACS(VNC) showed a significant underestimation (42.4 +/- 75.3 vs 67.3 +/- 88.3, P < 0.001, r = 0.94, ICC = 0.89; mean bias, 24.9; LoA, -87.1/37.2). In vivo comparison confirmed a high correlation but revealed an underestimation of CACS(PureCalcium) (169.3 [0.7/969.4] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.98; mean bias, -113.5; LoA, -470.2/243.2). In comparison, CACS(VNC) showed a similarly high correlation, but a substantially larger underestimation (24.3 [0/272.3] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.54; mean bias, -551.6; LoA, -2037.5/934.4). CACS(PureCalcium) showed superior agreement of CACS classification (kappa = 0.88) than CACS(VNC) (kappa = 0.60). Conclusions The accuracy of CACS quantification and classification based on PureCalcium reconstructions of CCTA outperforms CACS derived from VNC reconstructions.
更多
查看译文
关键词
calcium score, spectral imaging, coronary artery disease, photon counting detector
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要