Abstract The affordable, robust, compact (ARC) reactor is a tokamak fusion reactor concept currently under development by Commonwealth Fusion Systems (CFS)and Massachusetts Institute of Technology. There are three important neutronics considerations for the operation of the ARC reactor: (1) breeding of enough tritium in the blanket to sustain the D-T reaction in the plasma; (2) ensuring low fluence on the superconducting toroidal field coils; and (3) assessing neutron volumetric heating in structural components. This work aims to perform a validation of the neutronics analysis approach by code-to-code comparison. State-of-the-art software stacks are employed for the neutronics analysis of the ARC reactor, and a computer-aided design (CAD) model is used directly for Monte Carlo (MC) neutron transport calculations. Three software stacks, Attila-MCNP, OpenMC-DAGMC, and Shift-DAGMC, are used to perform neutronic analysesof a 90°sector CAD model of the ARC reactor. Results show that the flux tallies calculated by the three software stacks are very close. Also, the volumetric heatingand tritium breeding values have less than 0.6% relative difference between codes.