Patella Locking Star-Plate as Salvage to the Failed Tension Band Wiring for a Patella Fracture: A Case Report

Case Reports in Orthopedic Research(2022)

引用 1|浏览10
暂无评分
摘要
The integrity of the patella is pivotal for the efficient functioning of the knee extensor mechanism. Thus, patella fracture management cannot be neglected and utmost priority should be determined for its preservation and maintenance of knee functioning. Tension band wiring (TBW) is the most widely and commonly used mode of fixation of patella fractures with consistently favourable outcomes. However, the complications associated with the same could be challenging and may compromise the integrity of the patella. This case report highlights the salvage of the failed TBW for a patella fracture with biomechanically stronger angular stable Star-shaped patella plate.
更多
查看译文
关键词
failed,patella fracture,tension band,wiring,patella plate