Comparison of NH 3 and N 2 O Plasma Treatments on Bi 2 O 3 Sensing Membranes Applied in an Electrolyte-Insulator-Semiconductor Structure.

Membranes(2022)

Cited 1|Views3
No score
Abstract
In this study, bismuth trioxide (BiO) membranes in an electrolyte-insulator-semiconductor (EIS) structure were fabricated with pH sensing capability. To optimize the sensing performance, the membranes were treated with two types of plasma-NH and NO. To investigate the material property improvements, multiple material characterizations were conducted. Material analysis results indicate that plasma treatments with appropriate time could enhance the crystallization, remove the silicate and facilitate crystallizations. Owing to the material optimizations, the pH sensing capability could be greatly boosted. NH or NO plasma treated-BiO membranes could reach the pH sensitivity around 60 mV/pH and show promise for future biomedical applications.
More
Translated text
Key words
NH3 and N2O,bismuth trioxide,grainization,nitrogen passivation,plasma treatment