谷歌浏览器插件
订阅小程序
在清言上使用

OBIRCH for Isolating High and Low Resistance Test Structure Failures During Sub-14nm Technology Development

Proceedings - International Symposium for Testing and Failure Analysis(2018)

引用 1|浏览2
暂无评分
摘要
OBIRCH is a static technique for isolating both high and low resistance failures in test structures that continues to be relevant to sub 14nm technologies. While limited resolution is a factor as devices get smaller, an approximate location is adequate for finding obvious defects on sub 14nm technology structures. Its speed is what makes this technique appealing. If the approximate location isn’t good enough, a more time-consuming, higher-resolution technique can be employed. But the use of OBIRCH as a first isolation technique saves considerable time for a high volume FA lab if obvious defects cause the majority of failures. The seven case studies on sub 14nm technology are examples of obvious defects where OBIRCH had adequate resolution for isolation. The OBIRCH results for the first example are compared to the PVC (Passive Voltage Contrast) and EBAC (Electron-Beam Absorbed Current Imaging) findings to illustrate each technique’s strength and weakness.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要