Lung-Dependent Areas Collapse, Monitored by Electrical Impedance Tomography, May Predict the Oxygenation Response to Prone Ventilation in COVID-19 Acute Respiratory Distress Syndrome

CRITICAL CARE MEDICINE(2022)

引用 4|浏览23
暂无评分
摘要
OBJECTIVES: ICUs have had to deal with a large number of patients with acute respiratory distress syndrome COVID-19, a significant number of whom received prone ventilation, which is a substantial consumer of care time. The selection of patients that we have to ventilate in prone position seems interesting. We evaluate the correlation between the percentage of collapsed dependent lung areas in the supine position, monitoring by electrical impedance tomography and the oxygenation response (change in Pao(2)/Fio(2) ratio) to prone position. DESIGN: An observational prospective study. SETTING: From October 21, 2020, to 30 March 30, 2021. At the Sainte Anne military teaching Hospital and the Timone University Hospital. PATIENTS: Fifty consecutive patients admitted in our ICUs, with COVID-19 acute respiratory distress syndrome and required mechanical, were included. Twenty-four (48%) received prone ventilation. Fifty-eight prone sessions were investigated. INTERVENTIONS: An electrical impedance tomography recording was made in supine position, daily and repeated just before and just after the prone session. The daily dependent area collapse was calculated in relation to the previous electrical impedance tomography recording. Prone ventilation response was defined as a Pao(2)/Fio(2) ratio improvement greater than 20%. MEASUREMENT AND MAIN RESULTS: The main outcome was the correlation between dependent area collapse and the oxygenation response to prone ventilation. Dependent area collapse was correlated with oxygenation response to prone ventilation (R-2 = 0.49) and had a satisfactory prediction accuracy of prone response with an area under the curve of 0.94 (95% CI, 0.87-1.00; p < 0.001). Best Youden index was obtained for a dependent area collapse greater than 13.5 %. Sensitivity of 92% (95% CI, 78-97), a specificity of 91% (95% CI, 72-97), a positive predictive value of 94% (95% CI, 88-100), a negative predictive value of 87% (95% CI, 78-96), and a diagnostic accuracy of 91% (95% CI, 84-98). CONCLUSIONS: Dependent lung areas collapse (> 13.5%), monitored by electrical impedance tomography, has an excellent positive predictive value (94%) of improved oxygenation during prone ventilation.
更多
查看译文
关键词
acute respiratory distress syndrome, COVID-19, electrical impedance tomography, mechanical ventilation, oxygenation, prone position
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要