Using the technology of pressure jump, variations of temperature associated with pressure from 2.4 GPa to 4.6 GPa are measured for lead. The Gruneisen parameter is calculated from the thermodynamic relation γ = (Ks/T)(∂T/∂P)s, in which substitution of ΔT/ΔP for ∂T/∂P at median pressure is strictly justified. The correction of temperature change is carried out by analysing the experimental data, which makes the process more approaching to an adiabatic condition. The calculated values of ΔT/ΔP and γ gradually decrease with the increasing pressure. The decrease trend is consistent with the previous work. The γ values in the range of 2–3 GPa are averagely higher than the results of Ramakrishnan et al., indicating the effect of temperature correction. The improved method is promising for measurements of Gruneisen parameter to higher pressure range.