Local aortic aneurysm wall expansion measured with automated image analysis

JVS-Vascular Science(2022)

引用 1|浏览13
暂无评分
摘要
Background Assessment of regional aortic wall deformation (RAWD) might better predict for abdominal aortic aneurysm (AAA) rupture than the maximal aortic diameter or growth rate. Using sequential computed tomography angiograms (CTAs), we developed a streamlined, semiautomated method of computing RAWD using deformable image registration (dirRAWD). Methods Paired sequential CTAs performed 1 to 2 years apart of 15 patients with AAAs of various shapes and sizes were selected. Using each patient’s initial CTA, the luminal and aortic wall surfaces were segmented both manually and semiautomatically. Next, the same patient’s follow-up CTA was aligned with the first using automated rigid image registration. Deformable image registration was then used to calculate the local aneurysm wall expansion between the sequential scans (dirRAWD). To measure technique accuracy, the deformable registration results were compared with the local displacement of anatomic landmarks (fiducial markers), such as the origin of the inferior mesenteric artery and/or aortic wall calcifications. Additionally, for each patient, the maximal RAWD was manually measured for each aneurysm and was compared with the dirRAWD at the same location. Results The technique was successful in all patients. The mean landmark displacement error was 0.59 ± 0.93 mm with no difference between true landmark displacement and deformable registration landmark displacement by Wilcoxon rank sum test (P = .39). The absolute difference between the manually measured maximal RAWD and dirRAWD was 0.27 ± 0.23 mm, with a relative difference of 7.9% and no difference using the Wilcoxon rank sum test (P = .69). No differences were found in the maximal dirRAWD when derived using a purely manual AAA segmentation compared with using semiautomated AAA segmentation (P = .55). Conclusions We found accurate and automated RAWD measurements were feasible with clinically insignificant errors. Using semiautomated AAA segmentations for deformable image registration methods did not alter maximal dirRAWD accuracy compared with using manual AAA segmentations. Future work will compare dirRAWD with finite element analysis–derived regional wall stress and determine whether dirRAWD might serve as an independent predictor of rupture risk.
更多
查看译文
关键词
Aneurysms,Biomechanics,Computational analysis and simulation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要