Soft hybrid intrinsically motile robot for wireless small bowel enteroscopy

Surgical Endoscopy(2022)

引用 1|浏览17
暂无评分
摘要
Background Difficulties in establishing diagnosis of small bowel (SB) disorders, prevented their effective treatment. This problem was largely resolved by wireless capsule endoscopy (WCE), which has since become the first line investigation for suspected SB disorders. Several types of WCE pills are now used in clinical practice, despite their limitations and complications. WCE pills are large, rigid and immotile capsules. When swallowed, they provide SB enteroscopy downloaded to a data logger carried by the patient. Most of the complications of WCEs result from lack of intrinsic locomotion: incomplete examination, capsule retention and impaction within strictures. In addition, the rigid nature and size of current generation of WCE pills is accompanied by 0.1% inability to swallow the pill by patients with normal esophageal motility. Methods The aim of this communication is to describe the initial prototype, P 1 , which is thinner and slightly longer than the current generation of WCEs. In addition, it exhibits intrinsic active locomotion, produced by vibrating silicon legs. These generate a controlled-skid locomotion on the small bowel mucosal surface, rendered slippery by surface mucus and intraluminal surfactant bile salts. We demonstrate the mechanism responsible for the active locomotion of P 1 , which we consider translatable into a working prototype, suitable for further R&D for eventual clinical translation. Results The shape and attachment of the rubber vibrating legs to vibrating actuators, have been designed specifically to produce a tight clockwise circular motion. When inserted inside a circular tube in vitro of equivalent diameter to human small intestine, the intrinsic circular clockwise motion of P 1 translates into a linear locomotion by the constraints imposed by the surrounding circular walls of SB and rest of the gastrointestinal tract. This design ensures device stability during transit, essential for imaging and targeting lesions encountered during the enteroscopy. We preformed two experiments: (i) transit of P 1 through a phantom consisting of a segment of PVC tube placed on a horizontal surface and (ii) transit through a transparent slippery nylon sleeve insufflated with air. In the PVC tube, its transit rate averages 15.6 mm/s, which is too fast for endoscopy: whereas inside the very slippery nylon sleeve insufflated with air, the average transit rate of P 1 is reduced to 5.9 mm/s, i.e., ideal for inspection endoscopy. Conclusions These in-vitro experiments indicate that the P 1 hybrid soft robot prototype has the potential specifically for clinical translation for SB enteroscopy.
更多
查看译文
关键词
Enteroscopy,Wireless capsule endoscopy (WCE),Active vibration-induced locomotion,Active transit in small bowel
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要