Different cell imaging methods did not significantly improve immune cell image classification performance

PLOS ONE(2022)

引用 0|浏览14
暂无评分
摘要
Developments in high-throughput microscopy have made it possible to collect huge amounts of cell image data that are difficult to analyse manually. Machine learning (e.g., deep learning) is often employed to automate the extraction of information from these data, such as cell counting, cell type classification and image segmentation. However, the effects of different imaging methods on the accuracy of image processing have not been examined systematically. We studied the effects of different imaging methods on the performance of machine learning-based cell type classifiers. We observed lymphoid-primed multipotential progenitor (LMPP) and pro-B cells using three imaging methods: differential interference contrast (DIC), phase contrast (Ph) and bright-field (BF). We examined the classification performance of convolutional neural networks (CNNs) with each of them and their combinations. CNNs achieved an area under the receiver operating characteristic (ROC) curve (AUC) of similar to 0.9, which was significantly better than when the classifier used only cell size or cell contour shape as input. However, no significant differences were found between imaging methods and focal positions.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper