Lung stereotactic body radiation therapy: personalized PTV margins according to tumor location and number of four-dimensional CT scans

Pierre Trémolières,Ana Gonzalez-Moya,Amaury Paumier, Martine Mege, Julien Blanchecotte, Christelle Theotime,Damien Autret,Stéphane Dufreneix

RADIATION ONCOLOGY(2022)

引用 1|浏览1
暂无评分
摘要
Objectives To characterise the motion of pulmonary tumours during stereotactic body radiation therapy (SBRT) and to evaluate different margins when creating the planning target volume (PTV) on a single 4D CT scan (4DCT). Methods We conducted a retrospective single-site analysis on 30 patients undergoing lung SBRT. Two 4DCTs (4DCT1 and 4DCT2) were performed on all patients. First, motion was recorded for each 4DCT in anterior–posterior (AP), superior-inferior (SI) and rightleft (RL) directions. Then, we used 3 different margins (3,4 and 5 mm) to create the PTV, from the internal target volume (ITV) of 4DCT1 only (PTV D1 + 3, PTV D1 + 4, PTV D1 + 5). We compared, using the Dice coefficient, the volumes of these 3 PTVs, to the PTV actually used for the treatment (PTV ttt ). Finally, new treatment plans were calculated using only these 3 PTVs. We studied the ratio of the D2%, D50% and D98% between each new plan and the plan actually used for the treatment (D2% PTV ttt , D50% PTV ttt , D50% ITVttt D98% PTV ttt ). Results 30 lesions were studied. The greatest motion was observed in the SI axis (8.8 ± 6.6 [0.4–25.8] mm). The Dice index was higher when comparing PTVttt to PTV D1 + 4 mm (0.89 ± 0.04 [0.82–0.98]). Large differences were observed when comparing plans relative to PTVttt and PTV D1 + 3 for D98% PTV ttt (0.85 ± 0.24 [0.19–1.00]). and also for D98% ITV ttt (0.93 ± 0.12 [0.4–1.0]).D98% PTV ttt (0.85 ± 0.24 [0.19–1.00], p value = 0.003) was statistically different when comparing plans relative to PTV ttt and PTV D1 + 3. No stastistically differences were observed when comparing plans relative to PTV ttt and PTV D1 + 4. A difference greater than 10% relative to D98% PTV ttt was found for only in one UL lesion, located under the carina. Conclusion A single 4DCT appears feasible for upper lobe lesions located above the carina, using a 4-mm margin to generate the PTV. Advance in knowledge Propostion of a personalized SBRT treatment (number of 4DCT, margins) according to tumor location (above or under the carina).
更多
查看译文
关键词
Lung tumors,Stereotactic body radiation therapy,PTV margin,Motion study,Four dimensional computed tomography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要