A modified single-endobutton technique combined with nice knot for treatment of Rockwood type III or V acromioclavicular joint dislocation

BMC MUSCULOSKELETAL DISORDERS(2022)

引用 4|浏览3
暂无评分
摘要
Purpose Double-endobutton technique, as a widely accepted strategy for the treatment of acromioclavicular joint dislocation, is undergoing constant improvement. This study aims to assess the clinical effect of a modified single-endobutton combined with the nice knot in the fixation of Rockwood type III or V acromioclavicular joint dislocation. Methods From January 2016 to June 2019, 16 adult patients (13 males and 3 females) with Rockwood type III or V acromioclavicular joint dislocation were treated with a modified single-endobutton technique combined with the nice knot in our department. The age ranged from 18 to 64 years old with an average of 32.8 years old. Operative time, intraoperative blood loss, post-operative clinical outcomes and radiographic results were recorded and analyzed. Preoperative and last follow-up scores in the Constant-Murley Scale, Neer score, Rating Scale of the American Shoulder and Elbow Surgeons and VAS scale and complications such as infection, re-dislocation, implant loosening, medical origin fracture and hardware pain were recorded and evaluated. Results Sixteen patients were followed up for 6 to 18 months with an average of 10.3 months. The operative time was 50–90 min with an average of (62.5 ± 3.10) min. The intraoperative blood loss was 30–100 ml, with an average of (55.0 ± 4.28) ml. The complications, such as wound infection, internal fixation failure and fractures, were not found in these cases. According to Karlsson criteria, there were excellent in 14 cases, good in 2 cases at the final follow-up. The mean VAS score of the patients was 5.88 ± 0.26 preoperatively, compared with 0.19 ± 0.14 at the final follow-up evaluation. The difference was statistically significant ( P < 0.05). The mean Constant score was 45.5 ± 2.0 preoperatively, compared to 94.0 ± 0.73 at the final follow-up evaluation. The difference was statistically significant ( P < 0.05). Patients had statistically significant preoperative and postoperative AC (acromioclavicular distance) and CC (coracoclavicular distance) distances ( P < 0.05); 6 months postoperatively the AC( P = 0.412) and CC( P = 0.324) distances were not statistically significant compared to the healthy side. Conclusion Nice knot provides a reliable fixation for the single-endobutton technique in the treatment of acromioclavicular dislocations. The modified single-endobutton technique combined with the nice knot can achieve good clinical outcomes in the treatment of Rockwood type III or V acromioclavicular joint dislocation.
更多
查看译文
关键词
Acromioclavicular joint dislocation, Nice knot, Endobutton technique
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要