Combination of shear wave elastography and BI-RADS in identification of solid breast masses

Xue Zheng, Fei Li,Zhi-Dong Xuan,Yu Wang, Lei Zhang

BMC MEDICAL IMAGING(2021)

引用 4|浏览10
暂无评分
摘要
Background To explore the value of quantitative shear wave elastography (SWE) plus the Breast Imaging Reporting and Data System (BI-RADS) in the identification of solid breast masses. Methods A total of 108 patients with 120 solid breast masses admitted to our hospital from January 2019 to January 2020 were enrolled in this study. The pathological examination served as the gold standard for definitive diagnosis. Both SWE and BI-RADS grading were performed. Results Out of the 120 solid breast masses in 108 patients, 75 benign and 45 malignant masses were pathologically confirmed. The size, shape, margin, internal echo, microcalcification, lateral acoustic shadow, and posterior acoustic enhancement of benign and malignant masses were significantly different (all P < 0.05). The E mean, E max, SD, and E ratio of benign and malignant masses were significantly different (all P < 0.05). The E min was similar between benign and malignant masses ( P > 0.05). The percentage of Adler grade II-III of the benign masses was lower than that of the malignant masses ( P < 0.05). BI-RADS plus SWE yielded higher diagnostic specificity and positive predictive value than either BI-RADS or SWE; BI-RADS plus SWE yielded the highest diagnostic accuracy among the three methods (all P < 0.05). Conclusion SWE plus routine ultrasonography BI-RADS has a higher value in differentiating benign from malignant breast masses than color doppler or SWE alone, which should be further promoted in clinical practice.
更多
查看译文
关键词
BI-RADS,Shear wave elastography,Color doppler flow imaging,Solid breast mass,Diagnostic value
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要