Transient detection of either maldistribution or flowrate change in a counter current plate-fin heat exchanger using an ARX model

International Journal of Heat and Mass Transfer(2022)

引用 3|浏览3
暂无评分
摘要
•Linear systems with time constant coefficients have convolutive and ARX solutions.•ARX model of a transient inlet perturbation of a heat exchanger is calibrated.•Outlet temperature contrasts are signatures of structural changes/ calibration.•Exchanger malfunction NDT possible through transmittance and effectiveness changes.•These model and NDT technique are generic and apply to different types of exchanger.
更多
查看译文
关键词
Model identification,Parametric model,Convolution product,Inverse technique,Impulse response,Non-destructive testing