Transient detection of either maldistribution or flowrate change in a counter current plate-fin heat exchanger using an ARX model
International Journal of Heat and Mass Transfer(2022)
摘要
•Linear systems with time constant coefficients have convolutive and ARX solutions.•ARX model of a transient inlet perturbation of a heat exchanger is calibrated.•Outlet temperature contrasts are signatures of structural changes/ calibration.•Exchanger malfunction NDT possible through transmittance and effectiveness changes.•These model and NDT technique are generic and apply to different types of exchanger.
更多查看译文
关键词
Model identification,Parametric model,Convolution product,Inverse technique,Impulse response,Non-destructive testing