Thermally Assisted Optically Stimulated Luminescence Protocol Of Mobile Phone Substrate Glasses For Accident Dosimetry

RADIATION MEASUREMENTS(2021)

Cited 5|Views10
No score
Abstract
A thermally assisted optically stimulated luminescence protocol for the use of display glass samples from mobile phones as a fortuitous dosimeter was developed. Glass samples from 16 different mobile phones from the Samsung Galaxy series were used. The protocol consists of a prebleach with LEDs of 470 nm for 500 s and an OSL reading for 500 s at an elevated temperature. The decay curves were measured at different temperatures from 100 to 400 degrees C in an interval of 50 degrees C. A significant baseline increase in the decay curves was observed above 350 degrees C. For the TA-OSL below 300 degrees C, the dose response from 10 mGy to 10 Gy was linear and the signals were reproducible within 5% for six repeated readings. Compared with the residual thermoluminescence after an isothermal reading, the TA-OSL protocol showed lower zero doses at the given temperature. By increasing the temperature of the TA-OSL protocol from 100 to 300 degrees C, the minimum detectable dose increased from 17 to 70 mGy, but the fading rate reduced from 64% to 36% after 41 days from irradiation. In the optical stability test, strong reductions in TA-OSL signals were observed after exposures up to 1000 s with several light sources, and it was found that violet LEDs are more effective than blue LEDs for bleaching. As a result, the TA-OSL protocols investigated showed some improvements in terms of the lower minimum detectable doses and reduced fading rates compared with the prebleached thermoluminescence protocol.
More
Translated text
Key words
Retrospective dosimetry, Display glass, Thermally assisted optically stimulated, luminescence, Signal fading, Zero dose
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined