谷歌浏览器插件
订阅小程序
在清言上使用

Mixed-Mode Method Used For Pt100 Static Transfer Function Linearization

MEASUREMENT SCIENCE REVIEW(2021)

引用 3|浏览2
暂无评分
摘要
Pt100 is a resistance temperature detector characterized by a relatively linear resistance/temperature relationship in a narrow temperature range. However, the Pt100 sensor shows a certain degree of static transfer function nonlinearity of 4.42 % in the range between -200 degrees C and 850 degrees C, which is unacceptable for some applications. As a solution to this problem, a mixed-mode linearization method based on a special dual-stage piecewise linear ADC design is proposed in this paper. The first stage of the proposed dual-stage piecewise linear ADC is performed with a low-complex and low-power flash ADC of a novel sequential design. The novelty of the proposed sequential design is reflected in the fact that the number of employed comparators is equal to the flash ADC resolution. The second stage is performed with a delta-sigma ADC with a differential input and differential reference. Using the 6-bit flash ADC of novel design and the 24-bit delta-sigma ADC, the nonlinearity error is reduced to 2.6.10(-3) %, in the range between -200 degrees C and 850 degrees C. Two more ranges are examined, and the following results are obtained: in the range between 0 degrees C and 500 degrees C, the nonlinearity error is reduced from 1.99 % to 5.10(-4) %, while in the range between -50 degrees C and 150 degrees C, the nonlinearity error is reduced from 0.755 % to 2.15.10(-4) %.
更多
查看译文
关键词
Flash ADC, mixed-mode method, nonlinearity compensation, Pt100 static transfer function, sequential design
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要