Vacuum Packaging Technology Using Localized Aluminum/Silicon-To-Glass Bonding

14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST(2001)

Cited 95|Views0
No score
Abstract
A vacuum package based on localized aluminum/silicon-to-glass bonding has been successfully demonstrated. With 3.4 watts heating power, similar to0.2MPa applied contact pressure, and 90 minutes wait time before bonding, vacuum encapsulation at 25mtorr can be achieved. Folded-beam comb drive mu -resonators are encapsulated and used as pressure monitors. Long-term testing of un-annealed vacuum-packaged mu -resonators with a Q of 2500 has demonstrated stable operation after 20 weeks. A mu -resonator with Q of similar to 9600 has been vacuum encapsulated and shown to be stable after 7 weeks.
More
Translated text
Key words
Q-factor,aluminium,encapsulation,micromechanical resonators,microsensors,packaging,pressure sensors,silicon,25 mtorr,3.4 W,Al-Si,MEMS device,Q-factor,aluminum/silicon-to-glass bonding,folded beam comb drive microresonator,packaging technology,pressure monitor,vacuum encapsulation,
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined