Determination Of Aflatoxin B1 In Rice, Barley, And Feed By Non-Instrumental Immunochromatographic Strip-Test And High Sensitive Elisa

FOOD SCIENCE AND BIOTECHNOLOGY(2008)

Cited 0|Views0
No score
Abstract
A non-instrumental immunochromatographic (ICG) strip-test and direct competitive enzyme-linked immunosorbent assay (DC-ELISA) for aflatoxin B1 (AFB1) determination were developed and optimized. The detection limits of ICG strip-test and DGELISA were 0.5 and 0.004 ng/mL, respectively, and these methods possessed a cross-reaction to aflatoxins. The results of spiked samples by both inethods were coincided with the amount spiked AFB 1 and the comparative analyses of 172 real samples by 2 immunoassays and high performance liquid chromatography (HPLC) showed a good agreement. Especially, the lCG strip-test is easier to perform and quicker, but less sensitivity than DGELISA. Both inethods could analyze a high sample throughput with short time, but the sample throughput of ICG strip-test was better. Therefore, the lCG strip-test call be used as a simple, easy, non-instrumental, and fast screening technique for AFB1 determination.
More
Translated text
Key words
aflatoxin B1,mycotoxin,non-instrumental assay,immunochrornatographic strip-test (ICG),enzyme-linked,immunosorbent assay (ELISA)