Rest/stress myocardial perfusion imaging by positron emission tomography with 18 F-Flurpiridaz: A feasibility study in mice

biorxiv(2022)

引用 4|浏览8
暂无评分
摘要
Background Myocardial perfusion imaging by positron emission tomography (PET-MPI) is the current gold standard for quantification of myocardial blood flow. 18 F-flurpiridaz was recently introduced as a valid alternative to currently used PET-MPI probes. Nonetheless, optimum scan duration and time interval for image analysis are currently unknown. Further, it is unclear whether rest/stress PET-MPI with 18 F-flurpiridaz is feasible in mice. Methods Rest/stress PET-MPI was performed with 18 F-flurpiridaz (0.6-3.0 MBq) in 27 mice aged 7–8 months. Regadenoson (0.1 µg/g) was used for induction of vasodilator stress. Kinetic modeling was performed using a metabolite-corrected arterial input function. Image-derived myocardial 18 F-flurpiridaz uptake was assessed for different time intervals by placing a volume of interest in the left ventricular myocardium. Results Tracer kinetics were best described by a two-tissue compartment model. K 1 ranged from 6.7 to 20.0 mL·cm −3 ·min −1 , while myocardial volumes of distribution ( V T ) were between 34.6 and 83.6 mL·cm −3 . Of note, myocardial 18 F-flurpiridaz uptake (%ID/g) was significantly correlated with K 1 at rest and following pharmacological vasodilation for all time intervals assessed. However, while Spearman’s coefficients (r s ) ranged between 0.478 and 0.681, R 2 values were generally low. In contrast, an excellent correlation of myocardial 18 F-flurpiridaz uptake with V T was obtained, particularly when employing the averaged myocardial uptake from 20 to 40 min post tracer injection ( R 2 ≥ 0.98). Notably, K 1 and V T were similarly sensitive to pharmacological vasodilation induction. Further, mean stress-to-rest ratios of K 1 , V T , and %ID/g 18 F-flurpiridaz were virtually identical, suggesting that %ID/g 18 F-flurpiridaz can be used to estimate coronary flow reserve (CFR) in mice. Conclusion Our findings suggest that a simplified assessment of relative myocardial perfusion and CFR, based on image-derived tracer uptake, is feasible with 18 F-flurpiridaz in mice, enabling high-throughput mechanistic CFR studies in rodents.
更多
查看译文
关键词
Rest/stress myocardial perfusion imaging (MPI),positron emission tomography (PET),18f-flurpiridaz,kinetic modeling,regadenoson,coronary artery disease (CAD),microvascular dysfunction,myocardial ischemia,small animal PET,logan graphical analysis,tissue compartment model
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要