Outcomes of severe peripartum cardiomyopathy and mechanical circulatory support: a case series

Yuki Kiriyama, Yuki Kinishi, Daisuke Hiramatu,Akinori Uchiyama,Yuji Fujino,Koichi Toda,Chiyo Ootaki

JA CLINICAL REPORTS(2021)

引用 1|浏览9
暂无评分
摘要
Background We present three cases of severe peripartum cardiomyopathy (PPCM) that required mechanical circulatory supports. Case presentation Case 1: A 33-year-old woman developed acute heart failure (AHF) after normal spontaneous delivery. Intra-aortic balloon pump (IABP) was inserted on postpartum day (PD) 10 with a peripartum cardiomyopathy (PPCM), which was withdrawn on PD 30 after medical treatment including anti-prolactin drugs. Case 2: A 44-year-old woman developed AHF 1 month after vaginal delivery. IABP or extra-corporeal membrane oxygenation (ECMO) was not effective and a biventricular assist device was inserted. It was withdrawn on PD 85 after improvement of left ventricular ejection fraction (LVEF). Case3: A 37-year-old woman was transferred with a diagnosis of PPCM. Cardiac function unimproved by IABP or ECMO, and a left ventricular assist device was implanted. It was withdrawn on PD 386 after recovery of LVEF. Conclusion All the cases with PPCM recovered after mechanical circulatory supports and resumed social lives.
更多
查看译文
关键词
Cardiomyopathy,Heart failure,Pregnancy,Mechanical circulatory support,Bridge to transplantation,Bridge to recovery
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要