谷歌Chrome浏览器插件
订阅小程序
在清言上使用

EndoNaut two-dimensional fusion imaging with a mobile C-arm for endovascular treatment of occlusive peripheral arterial disease

Caroline Caradu,Katherine Stenson, Hassan Houmaida, Julie Le Ny,Florent Lalys,Eric Ducasse, Benoit Gheysens

Journal of Vascular Surgery(2022)

引用 4|浏览18
暂无评分
摘要
Background: Endovascular treatment has become the first-line strategy for peripheral arterial disease (PAD). Given the number of procedures required, any technology associated with a reduction in radiation exposure and contrast volume is highly relevant. In the present study, we evaluated whether two-dimensional (2D) fusion imaging could reduce the radiation exposure and contrast volume during endovascular treatment of occlusive PAD. Methods: Our consecutive, retrospective, single-center, nonrandomized comparative trial included patients with PAD at the femoral, popliteal, and/or tibial level, at any clinical stage, if they were candidates for endovascular revascularization. Patients were treated with or without the EndoNaut 2D fusion imaging system (Therenva, Rennes, France) in a nonhybrid room with the same Cios Alpha mobile C-arm (Siemens, Munich, Germany). The indirect dose-area product and contrast medium volume were recorded. Results: Between March 2018 and April 2020, 255 patients underwent endovascular femoropopliteal revascularization with (n = 124) or without (n = 131) 2D fusion imaging. The volume of injected contrast medium (34.7 +/- 13.8 mL vs 51.3 +/- 26.7 mL; P <.001) and dose-area product (8.9 +/- 9.9 Gy/cm(2) vs 13.5 +/- 14.0 Gy/cm(2); P=.003) were significantly lower for the 2D fusion imaging group than for the control group. A subgroup analysis of complex (TransAtlantic Inter-Society Consensus for the Management of Peripheral Arterial Disease C/D) lesions showed similar results. Stratification of the fusion imaging group into three subgroups, according to the procedure dates, showed no effect of a potential learning curve on the operative parameters. Conclusions: The results from the present study showed a significant reduction in the contrast volume and radiation dose for endovascular treatment of PAD when applying 2D fusion imaging technology. Overall, a reduction of >30% was observed for both operative parameters, without excessive training requirements, highlighting the potential benefits of using 2D fusion imaging when performing endovascular revascularization for PAD.
更多
查看译文
关键词
Artificial intelligence,Contrast agent,Flat panel,Fusion imaging,Hybrid room,Peripheral artery disease,Radiation protection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要