Total Aortic Arch Replacement Using The Thoraflex Hybrid Prosthesis: Early- And Medium-Term Results From A Scandinavian Center

SCANDINAVIAN CARDIOVASCULAR JOURNAL(2021)

引用 5|浏览2
暂无评分
摘要
Objective. The purpose of this study was to assess our early experience with the Thoraflex hybrid prosthesis. Design. This was a retrospective, single-center cohort study. Results. Between December 2014 and December 2019, 34 patients underwent total aortic arch replacement with the Thoraflex hybrid prosthesis. Fifteen of the patients had pre-operative chronic aortic dissection. The mean cardiopulmonary bypass time was 200 +/- 35 min, aortic cross clamp time 114 +/- 34 min, deep circulatory arrest time to the lower body 60 +/- 22 min, and selective antegrade cerebral perfusion time 67 +/- 24 min. The rate of stroke was 11.7% (4/34), paraparesis was 8.8% (3/34) and renal failure was 11.7% (4/34). No patient required permanent dialysis. Three (8.8%) patients died within the first 30 days postoperatively. All early deaths were due to stroke or spinal cord complications. During follow-up, an additional four patients died. Average follow-up was 32.4 +/- 19.4 months (1102 patient-months) and was 100% complete. Survival at 12 months and 36 months was 88% +/- 7.2% and 75% +/- 12.7%, respectively. Conclusions. The Thoraflex hybrid prosthesis can be used in the setting of total aortic arch replacement with good early- and medium-term results. Stroke and spinal cord complications remain an important source of early mortality.
更多
查看译文
关键词
Frozen elephant trunk, aortic arch surgery, thoracic aortic aneurysms
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要