Fracture strength of secondary crown with different taper and thickness in zirconia double crown attachments
DENTAL MATERIALS JOURNAL(2021)
摘要
The objective of this study was to clarify the influences of zirconia materials, one-half taper angle, and thickness of the secondary crown on the fracture strength of the secondary crown. For the primary and secondary crowns, Y-TZP and Ce-TZP/Al2O3 were used, respectively. Samples were prepared at one-half taper angles of 2 degrees and 4 degrees, and a secondary crown thickness of 0.5 and 1.0 mm (n=8). Regarding the fracture strength, the secondary crown was restored on the primary crown, all specimens were loaded until fracture using a universal testing machine. The load value added at the time of secondary crown fracture was regarded as fracture strength. Based on the analysis of variance, the fracture strength of Ce-TZP/Al2O3 was significantly higher than that of Y-TZP with regard to the material and that at 1.0-mm thickness was significantly higher than that at 0.5-mm thickness, but the taper angle had no influence.
更多查看译文
关键词
Double crowns, Y-TZP, Ce-TZP/Al2O3, Zirconia, Fracture strength