A Novel Plug-Based Vascular Closure Device for Percutaneous Femoral Artery Closure in Patients Undergoing Minimally-Invasive Valve Surgery

Andreas Schaefer, Harun Sarwari, Hermann Reichenspurner, Lenard Conradi

FRONTIERS IN CARDIOVASCULAR MEDICINE(2021)

Cited 1|Views3
No score
Abstract
Objectives: Surgical exposure of groin vessels to establish cardiopulmonary bypass (CPB) for minimally-invasive valve surgery (MIS) is standard of care but may result in postoperative wound healing disorders or seroma formation. Therefore, adaption of transcatheter techniques for fully percutaneous insertion of CPB cannulae may improve clinical results. We herein analyze a single center experience with a novel plug-based vascular closure device for MIS. Methods: Between 03/2020 and 02/2021 MIS using the MANTA (TM) (Teleflex Medical Inc., Wayne, PA, USA) vascular closure device was performed in 28 consecutive patients (58.8 +/- 10.6 years, 60.3% male, logEuroSCORE II 1.1 +/- 0.8%) receiving mitral and/or tricuspid valve repair/replacement. Concomitant procedures were left atrial appendage occlusion and cryoablation for atrial fibrillation in 21.4% (6/28) and 10.7% (3/28) of patients, respectively. Data were retrospectively analyzed in accordance with standardized M-VARC definitions. MANTA (TM) device success and early safety was defined as absence of any access site or access related vascular injury and major and life-threatening bleeding complications. Results: MANTA (TM) device success with immediate hemostasis and early safety were 96.4% (27/28). In one case, device failure necessitated surgical cut down without further complications. Mean aortic cross clamp time and cardiopulmonary bypass were 96.5 +/- 24.2min and 150.2 +/- 33.6min. Stroke, renal failure or myocardial infarction were not observed. Intensive care unit and total hospital stay were 1.7 +/- 0.8 days and 10.1 +/- 5.7 days. Overall 30-day mortality was 0%. Post-procedure echocardiography presented one case of residual moderate tricuspid regurgitation and competent valves in all other cases. Conclusions: The MANTA (TM) device is safe and effective in MIS. Its ease of use and effectiveness to achieve immediate hemostasis have further simplified MIS.
More
Translated text
Key words
mitral valve,tricuspid valve,minimally invasive cardiac surgery,cardiopulmonary bypass,vascular closure device
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined