Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration

SCIENTIFIC REPORTS(2021)

引用 3|浏览2
暂无评分
摘要
Water removal which is a key treatment goal of automated peritoneal dialysis (APD) can be assessed cycle-by-cycle using remote patient monitoring (RPM). We analysed ultrafiltration patterns during night APD following a dry day (APD DD ; no daytime fluid exchange) or wet day (APD WD ; daytime exchange). Ultrafiltration for each APD exchange were recorded for 16 days using RPM in 14 patients. The distributed model of fluid and solute transport was applied to simulate APD and to explore the impact of changes in peritoneal tissue hydration on ultrafiltration. We found lower ultrafiltration (mL, median [first quartile, third quartile]) during first and second vs. consecutive exchanges in APD DD (−61 [−148, 27], 170 [78, 228] vs. 213 [126, 275] mL; p < 0.001), but not in APD WD (81 [−8, 176], 81 [−4, 192] vs. 115 [4, 219] mL; NS). Simulations in a virtual patient showed that lower ultrafiltration (by 114 mL) was related to increased peritoneal tissue hydration caused by inflow of 187 mL of water during the first APD DD exchange. The observed phenomenon of lower ultrafiltration during initial exchanges of dialysis fluid in patients undergoing APD DD appears to be due to water inflow into the peritoneal tissue, re-establishing a state of increased hydration typical for peritoneal dialysis.