Removal of sticky silicone oil adhered to the retinal surface: comparison of methodological safety and effectiveness

INTERNATIONAL OPHTHALMOLOGY(2021)

Cited 0|Views4
No score
Abstract
Purpose To compare safety and effectiveness among methods to remove sticky silicone oil bubbles adhered to the retinal surface. Methods This retrospective nonrandomised case series included 14 eyes of 14 patients who had sticky silicone oil residue during silicone oil removal surgery. For small sticky silicone oil bubbles (< 2-disc diameter), aspiration was performed with a 23-gauge vitreous cutter. Residual tiny oil bubbles were then removed with a silicone-tipped flute needle or internal limiting membrane (ILM) peeling. For large sticky silicone oil bubbles (≥ 2-disc diameter) that could not be removed with a 23-gauge vitreous cutter, we devised a more efficient active removal method involving a modified 22-gauge venous indwelling cannula device. Results The mean preoperative best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR]) significantly improved from 1.28 ± 0.63 logMAR to 0.77 ± 0.58 logMAR ( p = 0.014). The postoperative BCVA and improvement in BCVA were significantly better in the ILM peeling group than in the non-ILM peeling group ( p = 0.004 and p = 0.045, respectively). Postoperative complications included residual sticky silicone oil bubbles in seven eyes without ILM peeling (50.0%), retinal neuroepithelial layer damage in two eyes (14.3%), and temporary hypotony in five eyes (35.7%). Conclusion Various methods can safely and efficiently remove sticky silicone oil bubbles adhered to the retinal surface. A 22-gauge venous indwelling cannula enabled simple and safe removal of large sticky silicone oil bubbles, while small residual sticky silicone oil bubbles could be completely removed by ILM peeling.
More
Translated text
Key words
Sticky silicone oil,Silicone oil removal,22-gauge venous indwelling cannula,Internal limiting membrane peeling
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined